Inspection Intelligence
A shingle-clad two-storey house with a wraparound porch

See through the house.

Ranked defects for the address and build year, from comparable inspections. Before you open the door, then a branded report the same day.

Request a demo

What this house is likely hiding

54%
Wiring and fire hazards Safety

Panel, branch circuits, exterior fixtures

Found in 54% of 412 comparable inspections of houses built 1970–1984 within three miles.

  1. Wiring and fire hazards
  2. Sewer line
  3. Radon
  4. Roof covering near end of life

Every decade left something behind.

Type or drag a build year. These are the defect families documented for houses of that era. In the app they are ranked for the exact address.

8 defect families documented for houses built in 1972
  • Cast-iron drain linesMajor

    Crack and scale with age; scope before closing.

    Before 1976
  • Clay sewer lateralMajor

    Joints let roots in; sewer scope recommended.

    Before 1981
  • Asbestos in insulation, tile or sidingSafety

    Common until the late 1970s; test, do not disturb.

    1920–1980
  • Lead-based paintSafety

    Banned for homes in 1978.

    Before 1979
  • Federal Pacific Stab-Lok panelSafety

    Breakers known to fail to trip.

    1950–1990
  • Zinsco panelSafety

    Breakers can fuse to the bus bar.

    1955–1980
  • Aluminum branch wiringSafety

    Loose, overheating connections at outlets.

    1965–1973
  • RadonSafety

    Depends on the ground, not the year. Test every house.

    Any year

Walk it offline. Every photo stamped.

A guided walkthrough built from your template. No signal in the crawl space? It saves on the phone and syncs when you are back up.

61 Pine Bluff Dr Offline · 14 waiting
Roof2 findings
Electrical3 findings
Attic1 finding
Crawl spaceIn progress
PlumbingNot started
Close-up of a 200-amp main breaker with its wiring
Main panel · double tap SafetyTue 4 Nov · 9:12 AM · 47.6588 N 117.4260 W
An attic with exposed rafters while insulation is blown in
Attic · insulation below R-38 MinorTue 4 Nov · 9:41 AM · 47.6588 N 117.4260 W
Floor beams seen from a crawl space
Crawl space · beam notched at bearing MajorTue 4 Nov · 10:20 AM · offline, synced 10:58
Bundles of shingles stacked on a roof ridge
Roof · shingles curling, south slope MajorTue 4 Nov · 11:05 AM · 47.6588 N 117.4260 W

Sent from the driveway.

Findings become a report in your company’s colours and logo, as a PDF and a client web view. You see when it lands and when it is first opened.

  • Branded PDF, versioned
  • Client link, revocable
  • Delivered and opened alerts
Ridgeline Home InspectionsInspection report · v1

61 Pine Bluff Dr

Built 1972 · Inspected Tue 4 Nov 2026 · Dana Ruiz, lic. 24-118

Safety 3Major 5Minor 9
Main panel · double tapTue 4 Nov · 9:12 AM
Safety
Attic · insulation below R-38Tue 4 Nov · 9:41 AM
Minor
Crawl space · beam notched at bearingTue 4 Nov · 10:20 AM
Major
Roof · shingles curling, south slopeTue 4 Nov · 11:05 AM
Major
Client opened the report61 Pine Bluff Dr · 1:20 PM

Open the door knowing.

Request a demo